IV-curve testing, electroluminescence, drone thermography, electrical safety checks and performance validation.
We build an inspection and test plan around your approved specifications, equipment documentation, risk profile and applicable IS/IEC requirements. Testing depth, sample size and acceptance criteria are agreed before mobilization.
What's included
- 01Module and string checks: visual defects, labels, serial traceability, polarity, measurements
- 02IV-curve testing to identify mismatch, shading, degradation and wiring faults
- 03Electroluminescence (EL) coordination to reveal cell cracks and latent defects
- 04Drone thermography to flag hotspots, inactive strings and bypass-diode anomalies
- 05Inverter and AC system checks against approved settings and manuals
- 06Insulation resistance, continuity, earthing, lightning protection and connector integrity
- 07Generation-data review and performance-ratio assessment
IV-curve
Electrical characterization to help identify mismatch, shading, degradation, wiring faults and abnormal behaviour.
Electroluminescence
EL testing through suitable equipment, mobile facilities or qualified partners to find cell cracks.
Thermography
Drone thermal survey of PV arrays to flag temperature patterns that need investigation.
Typical deliverables
- 01
Scope & document review
Confirm assets, specifications, drawings, acceptance criteria and responsibilities.
01/06 - 02
Inspection & test planning
Prepare a risk-based ITP, method statements, safety controls and required instruments.
02/06 - 03
Field or factory execution
Conduct agreed inspections, tests, sampling, witness points and evidence capture.
03/06 - 04
Findings & NCRs
Record deviations, classify risk and issue clear corrective-action requirements.
04/06 - 05
Verification & close-out
Review corrective actions, repeat agreed tests and update punch lists.
05/06 - 06
Final report & handover
Deliver traceable reports, an outstanding-item register and recommendations.
06/06